IS 407C toxic?
INHALATION: R-407C is low in acute toxicity in animals. When oxygen levels in air are reduced to 12-14% by displacement, symptoms of asphyxiation, loss of coordination, increased pulse rate and deeper respiration will occur. Some effects of inhalation and skin exposure would be expected.
What is 407C made of?
Product summary. R-407C is a non-azeotropic mixed refrigerant composed of the three ingredients R-32, R-125, and R-134a, and was developed as a substitute refrigerant for R-22, used in applications such as air conditioning equipment and chiller equipment for medium temperature ranges.
What is R407C refrigerant used for?
R407C is predominantly used in commercial and residential air conditioning systems and has very similar properties to R22. With the quota enforced decrease in R22 use, R407C has been used as an alternative to R22 in new equipment, it is also being used to replace R22 in some existing system retrofits.
Is R407C CFC free?
R407C is a kind of CFC-free refrigerant that does not deplete the ozone layer. With similar compressor capacity, system temperature and pressure to R22, it is considered as a direct substitute with features as follows: The refrigerant should be liquefied when added into the system.
IS 407C lighter than air?
Refrigerant Gas R407C is a colorless odorless gas. It is shipped as a liquid under its own vapor pressure. The vapors are heavier than air and can cause asphyxiation. By the displacement of air.
What is the difference between R407A and R407C?
Also, R407C exhibits a lower power consumption than that of the R22 tests by a value ranging between (3%) and (4%). On the contrary, R407A shows a higher power consumption than that of R22 by a value ranging between (4%) and (10%).
Can I use 407C instead of 134a?
Re: Why can’t I top up my R407C air con with R134a Don’t worry, ofcourse you can use the same gas in all of them.
What is the replacement for R407C?
Replacement refrigerants for R407C The replacements or alternative refrigerants for R407C include R32 and R444B as well as other various mixtures of HFO refrigerants.
What pressure is 407C?
Recovery of R-407C requires a cylinder with a service pressure of 300 psig minimum. If this is so always evaporating above zero, 4 or 5 deg celcius, R407c will have a low pressure (suction ) of about 50 psi.
Where can I find the safety data sheet for R-407C?
SAFETY DATA SHEET 1) CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME : R-407C OTHER NAME : Difluoromethane, Pentafluoroethane, 1,1,1,2- Tetrafluoroethane USE : Refrigerant Gas SUPPLIER : Global Refrigerants (s) PTE. LTD. 9 TUAS LINK 1, SINGAPORE 638587 2) HAZARDS IDENTIFICATION
Who is the manufacturer of Freon 407C refrigerant?
Product name : Freon™ 407C (R-407C) Refrigerant SDS-Identcode : 130000000517 Manufacturer or supplier’s details Company name of supplier : The Chemours Company FC, LLC Address : 1007 Market Street Wilmington, DE 19801 United States of America (USA) Telephone : 1-844-773-CHEM (outside the U.S. 1-302-773-1000) Emergency telephone
What is the product identifier for refrigerant gas R134a?
REFRIGERANT R134A SECTION 1: IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY / UNDERTAKING 1.1. Product Identifier Product Name: REFRIGERANT R134a Synonyms: 1,1,1,2 Tetrafluoroethane HFC-134a Norflurane EC Number: 212-337-0 CAS Number: 811-97-2 REACH Registration Number: 01-2119459374-33-0002
What is the product name of global refrigerants?
PRODUCT NAME : R-407C OTHER NAME : Difluoromethane, Pentafluoroethane, 1,1,1,2- Tetrafluoroethane USE : Refrigerant Gas SUPPLIER : Global Refrigerants (s) PTE. LTD. 9 TUAS LINK 1, SINGAPORE 638587 2) HAZARDS IDENTIFICATION